XH‑3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller

9,95 €
+ 1,99 € Αποστολή

XH‑3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller

  • Μάρκα: Unbranded
Πωλήθηκε από:

XH‑3002 Microcomputer Digital Temperature Controller Hatching Temperature Controller

  • Μάρκα: Unbranded

9,95 €

Αποθήκευση 6,00 € (37%)

Συνιστώμενη τιμή

15,95 €
Σε απόθεμα
+ 1,99 € Αποστολή
Πωλήθηκε από:

9,95 €

Αποθήκευση 6,00 € (37%)

Συνιστώμενη τιμή

15,95 €
Σε απόθεμα
+ 1,99 € Αποστολή

Δεχόμαστε τους ακόλουθους τρόπους πληρωμής

Περιγραφή

1、A variety of fields perfect use, convenient operation and practical settings, is your side temperature control housekeeper. 2、It is precise and reliable with good long‑term stability. Convenient for install and fixed. Small size, low power consumption, fast response. 3、Easy operation, to set start temperature, stop temperature, corrected temperature connector and so on. 4、Suitable for hatching, breeding, air and water temperature control and other related temperature detection and control. 5、Specifications are optional, precise temperature control, temperature calibration. 1 x Temperature Controller    ItemType: Digital Temperature ControllerMaterial: PlasticWeight: Approx. 51g / 1.8ozOperating Voltage Specifications: 12V, 24V, 110-220VAccuracy Level: 0.1Temperature Measurement Range: -50-110 (℃)Temperature Measurement Accuracy: -15-65 (℃)Humidity Measurement Accuracy: 1 (RH)Temperature Measurement Error: ±1 (℃)Applicable Environment: -15-55℃ / 20%-85%RHProduct Embedded Hole Size: 73mm / 2.9in, Hole Diameter (φ4mm)How to use: 1. Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required starting temperature through the up and down buttons. 2. Press the setting key once to enter the internal menu, the display is P0, switch to P1 through the up and down keys, press the setting key again, and set the required stop temperature through the up and down keys. 3. Enter the internal menu in the same way, switch to P2 through the up and down buttons, press the setting button again, and set the required calibration temperature through the up and down buttons. (Note: In the setting, if the detected temperature value is 0.5°C larger than the actual temperature value, then the calibration temperature that needs to be set is - 0.5°C. If the detected value is 1°C lower than the actual temperature value, the calibration temperature that needs to be set is 1°C. Detection temperature + Correction temperature = Actual temperature.) 4. Enter the internal menu in the same way, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time through the up and down buttons in minutes. (Note: Delayed start is generally used for compressor refrigeration. If it is used for refrigerators and freezers, this value needs to be set. According to the compressor back pressure, the general setting value is 3-6 minutes. If you are not used for control or no delay function is needed, just skip it.Temperature control mode 1. Setting essentials:Start temperature <stop temperature (the program automatically judges that the working mode is heating mode) 2. Setting method: press the setting key to enter the internal menu, set the start temperature through the P0 value, and set the stop temperature through the P1 valueUse case: Control the water heater, stop heating to 50°C, and start heating again when the temperature returns to 40°C, how to set it? 1. Make sure that the working mode is heating mode, starting temperature <stop temperature. 2. Press the setting key to enter the internal menu, select P0 to start the temperature and set the P0 value to 40°C. 3. Press the set key to enter the internal menu, select P1 to stop the temperature and set the value of P1 to 50℃Cooling mode 1. Setting essentials: start temperature> stop temperature (the program automatically judges that the working mode is cooling mode) 2. Setting method: Press the setting key to enter the internal menu, set the start temperature through the P0 sets the stop temperature through the P1 value.Use case: empty cabinet radiator, heat dissipation stops at 26℃, and the temperature rises to 30℃ to start the radiator again, how to set it? 1. Make sure the working mode is cooling mode, starting temperature>stop temperature. 2. Press the setting key to enter the internal menu, select P0 to start the temperature change and set the P0 value to 30°C. 3. Press the setting key to enter the internal menu, select P1 to stop the temperature and set the value of P1 to 26℃.
  • Fruugo ID: 352888513-768229419
  • EAN: 9349522363899

Πληροφορίες για την ασφάλεια του προϊόντος

Δείτε τις πληροφορίες για την ασφάλεια του προϊόντος που περιγράφονται παρακάτω

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Προειδοποιήσεις για την ασφάλεια: Warning: You need to check the safety performance of the device regularly to ensure that the device is in good condition.

Παράδοση & Επιστροφές

Αποστέλλεται σε 3 μέρες

  • STANDARD: 1,99 € - Παράδοση μεταξύ Δευ 17 Νοεμβρίου 2025–Τετ 19 Νοεμβρίου 2025

Αποστέλλεται από Κίνα.

Κάνουμε ό,τι καλύτερο μπορούμε για να εξασφαλίσουμε ότι τα προϊόντα που παραγγέλνετε αποστέλλονται σε εσάς πλήρως και σύμφωνα με τις προδιαγραφές σας. Παρ' όλα αυτά, αν παραλάβετε μία ελλιπή παραγγελία ή προϊόντα διαφορετικά από αυτά που παραγγείλατε ή αν υπάρχει κάποιος άλλος λόγος που δεν είστε ικανοποιημένοι με την παραγγελία, μπορείτε να την επιστρέψετε ολόκληρη ή κάποια προϊόντα από αυτή και να λάβετε πλήρη επιστροφή χρημάτων για τα προϊόντα. Προβολή πλήρους πολιτικής επιστροφών

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Κατασκευαστής:
Οι παρακάτω πληροφορίες αφορούν τα στοιχεία επικοινωνίας του κατασκευαστή του σχετικού προϊόντος που πωλείται στο Fruugo.

  • Chen ShaoMao
  • Lixian Maisite Trading Co., Ltd.
  • Group 8
  • Wugong Tun
  • Lixian Changde
  • Changde
  • CN
  • 415506
  • Zhouxiaopengzxp@outlook.com
  • 13207704292

Υπεύθυνος στην ΕΕ:
Οι παρακάτω πληροφορίες αφορούν τα στοιχεία επικοινωνίας του επευθύνου στην Ε.Ε. Ο υπεύθυνος είναι ο καθορισμένος οικονομικός φορέας που εδρεύει στην Ε.Ε. και είναι υπεύθυνος για τις υποχρεώσεις συμμόρφωσης που αφορούν το σχετικό προϊόν που πωλείται στην Ευρωπαϊκή Ένωση.

  • e Vatmaster Consulting GmbH
  • e Vatmaster Consulting GmbH
  • RaiffeisenstraBe 2 B11
  • Rodgau
  • DE
  • 63110
  • contact@evatmaster.com
  • 49 61062699873