Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

37,95 €
+ 18,49 € Αποστολή

Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

  • Μάρκα: Unbranded
Πωλήθηκε από:

Digital display meter 0-10V 0-20mA 2-10V 4-20mA analog input display table Digital display head

  • Μάρκα: Unbranded
Αρχική τιμή: 49,00 €
Τιμή: 37,95 €
Κερδίζετε: 11,05 € (22%)
Πωλήθηκε από:
37,95 €
+ 18,49 € Αποστολή

Σε απόθεμα

Δεχόμαστε τους ακόλουθους τρόπους πληρωμής

Περιγραφή

1. The meter can be called a universal analog input display meter. It can be matched with various sensors with analog output to display the actual physical quantity. Such as temperature transmitter, frequency converter, motor speed, preure, liquid level, concentration, etc. 2. The instrument supports current input or voltage input. 3. Default adaptation: 0-10V, 2-10V, 0-20mA, 4-20mA. By setting the bias parameter and gain parameter, it can adapt to other inputs in the range of 0-10V, or 0-20mA. 4. It is displayed as a percentage by default. You can also set your own display range through F0-2 ~ F0-4. 5. The instrument with 485 interface has already supported the communication between the meters, and it is convenient to realize multiple displays. Main features Model description,standard version: HXDSBOXAI-NR;With RS485 version: HXDSBOXAI-485;With relay output version: HXDSBOXAI-RL Standard version and version with RS485, rated power supply voltage range: DC6~25V, power consumption: 24V/40mA;with relay output version, rated power supply voltage Range: DC8~25V, powerconsumption: 24V/50mA;power supply anti-reverse connection and surge protection 1 analog input, voltage type or current type can be selected Voltage type input impedance: >30kQ, current type input impedance: "With RS485 version", using standard Modbus-RTU protocol, easy to achieve networking: and support networking between tables,"With relay output version", with 1 normally open relay output, relay load capacity: 3A30Dc/3A250VAC; Mechanical size: 794325mm: installation opening: 76.539.5mm. Indicator light and signal description 1.Front panel diagram 2. Indicator light: a. Only "with RS485 version" is useful: R communication receives data indication: T communication sends data indication b. Only the "with relay output version" has: S indicator light on when the relay is closed 3.Port signal description signal Explanation PWR Connectto the positive pole of the power supply (standard version and versionwith RS485: DC6~30V: with relay output version: DC8~30V) GND Power and signal ground Ai Power and signal ground mA Current-type analog input signal configuration interface, short-circuited with A, then configured as current-type input WithRS485 version 485- RS485 signal is negative 485+ RS485 signal is positive With relay outputversion KA Relay normally open contact output port KB 4.Common wiring diagram: 5. Button and digital tube display state transition diagram: Special note: In the third-level menu, click OK to save the modified parameter value and return to the previous menu, the parameter number is automatically increased by one; and click the SET button to directly return to the previous menu without saving the modified parameter value .Long pre or to make the adjustment value change quickly. Parameter description The parameters are described as follows: 1.F0 Attendant array display Parameter parameter name Scope and description Defaults Read write F0-0 Collected value monitoring Monitor the percentage of the current analog input value. Range: 0-100.0% read-only F0-1 Display value monitoring In the display value in "Monitoring Menu" is calculated by F0-0, F0-2~F04. read-only F0-2 Display accuracy The number of decimal places displayed in the "Monitor Menu", range: 0-3. 1 Read write F0-3 Show minimum In the "monitoring menu", the value corresponding to "acquisition value" is 0%, the range: -1999~9999 0 Read write F0-4 Show maximum In the "Monitoring Menu", the value corresponding to the "Acquisition Value" is 100.0%, the range: 1999~9999 1000 Read write F0-5 Offline status 0: Not disconnected; 1: Disconnected. (Disconnection detection is set by F1-4) (starting from V2.10) read-only 2.F1 parameter group-analog configuration parameters Parameter parameter name Scope and description Defaults Read write F1-0 Input type selection 0: 0~10V or 0~20mA corresponds to 0~100.0%; 1: 2~10V or 4~20mA corresponds to 0~100.0%, and 0 when it is lower than 2V or 4mA. 0 Read write F1-1 Input filter time Analog input filter time, range: 0~10.000s. The longer the filtering time, the stronger the filtering 0.200 Read write F1-2 Input gain Range: 0~1000.0%. 100.0 Read write F1-3 Input offset -99.9~99.9%, with 10V or 20mA as 100.0%. 0.0 Read write F1-4 Drop detection threshold Range: 0.0-100.0%. This value is based on 0-10V or 0-20mA as 0.0-100.0% as a reference (and F1-0 and gain offset are not related), the detection is not started if it is le than 0.5, and there is a hysteresis of 0.3. When the input signal is lower than this value, the meter displays E.oFL. (Starting from V2.10) 0.0 Read write F1-5 Enter the parameter setting select
  • Fruugo ID: 279403132-621274316
  • EAN: 9085801629309

Πληροφορίες για την ασφάλεια του προϊόντος

Δείτε τις πληροφορίες για την ασφάλεια του προϊόντος που περιγράφονται παρακάτω

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Ετικέτες ασφάλειας προϊόντων

CE Mark
Προειδοποιήσεις για την ασφάλεια:
  • Keep out of reach of children: Prevent accidental ingestion, misuse, or harm.
  • Always follow instructions: Ensures proper usage and prevents malfunctions or accidents.

Παράδοση & Επιστροφές

Αποστέλλεται σε 24 ώρες

  • STANDARD: 18,49 € - Παράδοση μεταξύ Πέμ 16 Οκτωβρίου 2025–Παρ 24 Οκτωβρίου 2025

Αποστέλλεται από Κίνα.

Κάνουμε ό,τι καλύτερο μπορούμε για να εξασφαλίσουμε ότι τα προϊόντα που παραγγέλνετε αποστέλλονται σε εσάς πλήρως και σύμφωνα με τις προδιαγραφές σας. Παρ' όλα αυτά, αν παραλάβετε μία ελλιπή παραγγελία ή προϊόντα διαφορετικά από αυτά που παραγγείλατε ή αν υπάρχει κάποιος άλλος λόγος που δεν είστε ικανοποιημένοι με την παραγγελία, μπορείτε να την επιστρέψετε ολόκληρη ή κάποια προϊόντα από αυτή και να λάβετε πλήρη επιστροφή χρημάτων για τα προϊόντα. Προβολή πλήρους πολιτικής επιστροφών

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Κατασκευαστής:
Οι παρακάτω πληροφορίες αφορούν τα στοιχεία επικοινωνίας του κατασκευαστή του σχετικού προϊόντος που πωλείται στο Fruugo.

  • Shenzhenshi Sinizefushi Youxiangongsi
  • Shenzhenshi Sinizefushi Youxiangongsi
  • 606, Mingcheng International Plaza, Longgang Avenue, Maoye community,
  • Buji street, Longgang District
  • Shenzhen
  • CN
  • 518000
  • alitianmei@163.com
  • 13265018442

Υπεύθυνος στην ΕΕ:
Οι παρακάτω πληροφορίες αφορούν τα στοιχεία επικοινωνίας του επευθύνου στην Ε.Ε. Ο υπεύθυνος είναι ο καθορισμένος οικονομικός φορέας που εδρεύει στην Ε.Ε. και είναι υπεύθυνος για τις υποχρεώσεις συμμόρφωσης που αφορούν το σχετικό προϊόν που πωλείται στην Ευρωπαϊκή Ένωση.

  • JUAN SERRANO GONZALEZ SOCIEDAD LIMITADA
  • JUAN SERRANO GONZALEZ SOCIEDAD LIMITADA
  • C/PABLO IGLESIAS 1-A-ENTRESUELO
  • CASTELLON DE LA PLANA
  • Spain
  • 12006
  • alitianmei@163.com
  • 0034 964 867178