Περιγραφή
Humidity Temperature Control Module Digital Display 2 Output Relay Board Sensor DC630V XYTR01
Item Type: Humidity Temperature Control Module
Product Model: XY-TR01
Temperature Measurement Range: -20℃~60℃
Humidity Range: 0%~100%RH
System Accuracy: 0.1℃ 0.1%RH
Detection Probe: Integrated sensor
Output Type: Relay output
Output Capacity: Maximum 10A
The Temperature Function is As Follows:
1. Automatic Recognition of Working Mode:
The system automatically recognizes the working mode according to the start temperature and stop temperature;
Starting temperature>stop temperature, cooling mode ‘C’; starting temperature <stop temperature, heating mode ‘H’;
2. Cooling Mode:
When the detection temperature ≥ the starting temperature, the relay is turned on, the red indicator light is on, and the refrigeration equipment starts to work;
When the detected temperature is less than or equal to the stop temperature, the relay is turned off, the red indicator light is off, and the refrigeration equipment stops working;
3. Heating Mode:
When the detection temperature is less than the start temperature, the relay is turned on, the red indicator light is on, and the heating device starts to work;
When the detected temperature is greater than or equal to the stop temperature, the relay is closed, the red indicator light is off, and the heating device stops working
4. Temperature Correction Function OFE (-10.0 ~ 10.0℃):
The system works for a long time, and there may be deviations. Through this function, the actual temperature = measured temperature + calibration value;
How to Set the Start and Stop Temperature:
1. In the running interface, press and hold the ‘TM+’ key for more than 3 seconds to enter the startup temperature setting interface. The test can be used to modify the parameters through the TM+ TM- keys. After the parameter modification is completed, wait for 6 seconds to automatically exit and save;
2. In the running interface, press and hold the ‘TM-’ key for more than 3 seconds to enter the stop temperature setting interface. The test can be used to modify the parameters through the TM + TM- keys. After the parameter modification is completed, wait for 6 seconds to automatically exit and save;
Humidity Functions Are as Follows:
1. Automatic Recognition of Working Mode:
The system automatically recognizes the working mode according to the start humidity and stop temperature;
Start humidity> stop humidity, dehumidification mode ‘d’; start humidity <stop humidity, humidification mode ‘E’;
2. Dehumidification Mode:
When detecting humidity ≥ start humidity, the relay is turned on, the green indicator light is on, and the dehumidification equipment starts to work;
When the detected humidity is less than or equal to the stop humidity, the relay is closed, the green indicator light is off, and the dehumidification equipment stops working;
3. Humidification Mode:
When the detected humidity is less than the start humidity, the relay is turned on, the green indicator light is on, and the humidifying device starts to work;
When detecting humidity ≥ stop humidity, the relay is turned off, the green indicator light is off, and the humidifying device stops working
4. Humidity Correction Function RH (-10.0 ~ 10.0℃):
The system works for a long time, and there may be deviations. Through this function, the actual humidity = measured humidity + calibration value;
How to Set Start and Stop Humidity:
1. In the running interface, press and hold the ‘RH+’ key for more than 3 seconds to enter the start humidity setting interface. The test can be used to modify the parameters through the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save;
2. In the running interface, press and hold the ‘RH-’ key for more than 3 seconds to enter the stop humidity setting interface. The test can be used to modify the parameters through the RH+ RH- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save;
Operation Interface Description:
Working mode display. After the start temperature and humidity, stop temperature and humidity and other parameters are set, the current mode ("H/C", "E/d") will be displayed in front of the temperature and humidity;
When any relay is turned on, the upper left corner of the interface displays "OUT". If the temperature relay is turned on, the temperature operating mode "H/C" flashes to indicate a reminder; if the humidity relay is turned on, the humidity operating mode "E" flashes /d", as a reminder;
Other Functions:
1. Remote Parameter Reading/Setting:
You can set parameters such as start temperature and humidity, stop temperature and humidity, and temperature and humidity correction through UART;
2. Real Time Reporting of Temperature and Humidity:
If the temperature and humidity report function is turned on, the product will detect the temperature and humidity and rel
-
Fruugo ID:
412915274-872901720
-
EAN:
4661337012812